The bar must be 1 1 4 to 1 1 2 inches in diameter.
Ada compliance ada grab bar requirements 2020. A summary of these requirements is below. Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface. Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall. Know what the ada code is for bathroom grab bars in an accessible bathroom grab bars are critical whether they are in a shower stall or around a toilet.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed. The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min. Grab bars in toilet stall requirements. The toilet paper dispenser should be between 7 inches and 9 inches in front of the toilet.
Toilets need to have horizontal bars behind and next to them and a vertical bar in front. 29 except that grab bars shall be mounted 18 in minimum to 27 in maximum 455 mm to 685 mm above the finish floor measured to the grab bar centerline. Grab bars for water closets not located in stalls shall comply with 4 26 and fig. Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
Grab bars are mounted 33 36 inches 840 915 mm above the finish floor. Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches. Grab bars are not intended to be used as towel bars and vice versa. Grab bar code requirements are included in the standard ansii icc a117 1 of the international code council.
The 36 inches 915 mm wide stall shall have parallel grab bars on the side walls. Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall. The dispenser should be 13 inches and 48 inches above the floor and should not be located behind the side grab bar and should be appropriately positioned in an area that complies with the ada standard. Toilet paper dispensers 604 7 toilet paper dispensers must be within accessible reach from the water closet.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.